When expectations and
outcomes align

Patient expectations from lens surgery are changing, with an increasing desire to be spectacle free as they continue to lead highly active and social lifestyles until much later in life.

Whether your patients are having cataract surgery or visiting you for refractive enhancement, our complete family of trifocal IOLs are clinically proven to provide them with the best visual outcomes.

 

Rayner Trifocal IOL Family

Optimised diffractive design

Our family of trifocal IOLs use Rayner’s patented diffractive profile that was designed in partnership with a leading European technology institute. This new design of diffractive technology is the most advanced optic in our history and possibly the most advanced in the industry. The diffractive surface is a construct of two profiles to form our patented design:

Graphical representations only of diffractive surface pattern.

FEATURES
• 16 diffractive rings/steps
• 4.5 mm diffractive zone
• >4.5 mm monofocal, distance

PATIENT BENEFITS
• Reduces visual disturbances
• Developed to be less dependent on pupil size or lighting conditions
• Improves distance vision in mesopic condition

 

Our patented diffractive step trifocal
technology reduces light loss to only 11%

• 89% of light is transmitted to the retina with a pupil of 3.0 mm
• Half the light is allocated for distance
• Remaining light is divided between near and intermediate vision


Light energy split with a 3.0 mm pupil:

Comfortable transition from near to distance activities

Our trifocal optic improves intermediate visual acuity, enabling patients to feel more comfortable transitioning from near to distance activities

Clinically-proven and industry leading trifocal technology

Comparable outcomes
In a retrospective study of RayOne Trifocal and Sulcoflex Trifocal in 40 eyes, the defocus curve shows comparable visual acuity results and reports similar outcomes.1

Less photic phenomena

In a prospective study of 60 eyes, a statistically significant difference favouring the RayOne Trifocal versus the FineVision POD F was achieved in an objective evaluation of photic phenomenon.2

Less photic phenomena and increased patient satisfaction

In a prospective comparative study of 64 eyes of 32 patients, the RayOne Trifocal group is associated with better scores for glare, symptoms and near and distance VA against the PanOptix Trifocal group.15

100% spectacle independence

In a prospective study of 16 eyes implanted with RayOne Trifocal, 100% of patients achieved spectacle independence and agreed they would have the operation again at 1 month follow up.3

Download Trifocal IOL Brochure

 

Learn more

1.Eurotimes Supplement Feb 2019. RayOne Trifocal & Sulcoflex Trifocal. 2.Ferreira TB and Ribeiro FJ. J Refract Surg. 2019;35(7):418-425. 3.De Lange J. Ophthalmology Times Europe article March 2019. 15. Data on file, Jan 2021.